REM modul

REM modul REM modul hero scaled
REM modul REM rem modul ikone

Speed and versatility

The REM modul modular construction system allows a wide range of applications to construct simple or complex prefabricated buildings. Its design makes it easy to set up the desired facility and to start using it quickly.

REM modul REM rem modul 2

Construction

The unit is designed as a two-axis steel moment frame. Secondary beams transmit the loads to the primary beams, and from there the forces are transmitted to the corner posts via rigidly designed ceiling and floor corner fittings.
REM modul REM modul konstrukcija mob 1

Standard exterior dimensions

The basic exterior dimensions of standard living units are described in the table below.

Unit type

Unit length

Unit width

Unit height

10"

2,989 m

15"

4,550 m

16"

4,880 m

20"

6,055 m

24"

7,325 m

30"

9,125 m

2, 435 m

2,591 m / 2,741 m1;
(NV=2,326 m)

2,765 m / 2,915 m1;
(NV=2,500 m)

Steel frame protection

As a standard, a coating system that provides the C3 class of protection (ISO 12944-2:2018) is used.

Anti-corrosion protection of the steel frame

Coating system

Coating thickness based on ISO 12944-6 (μm)

Corrosion category of the coating (ISO 12944-2)

Coating type

Coating durability ISO 12944-1

1

120 μm

C3 - M

2

180 μm

C4 - M

3

240 μm

C5 - M

Single-layer polyurethane coating
7 to 15 years

Anti-corrosion protection of steel frame - applied on hot-dip galvanized surface

Coating system

Coating thickness based on ISO 12944-6 (μm)

Corrosion category of the coating (ISO 12944-2)

Coating type

Coating durability ISO 12944-1

1

80 μm

C3 - M

2

120 μm

C4 - M

3

160 μm

C5 - M

Single-layer
polyurethane
coating

7 to 15 years
The modular units require pad, strip or slab foundations. The recommended foundation type depends on individual projects specifications.

Static design of the units

The unit is designed as a two-axis steel moment frame. Secondary beams transmit the loads to the primary beams, and from there the forces are transmitted to the corner posts via rigidly designed ceiling and floor corner fittings. At the same time, the floor corner fittings also transfer the unit loads to the foundation floor. The unit dimensions and particular load-bearing elements can be adapted to the needs of the building in question and the bearing of loads acting on it.

Units that do not fall within the standard dimensions and standard permissible loads can also be manufactured. In such cases, it is necessary to conduct the static verification of the unit frame, which will serve as the basis for appropriate unit construction.

Extreme flexibility

The figures above are used for informational purposes only. Individual unit elements can be customised to your requirements.

Ceiling

In addition to the top insulation layer, the ceiling of REM modules also acts as a primary roof, ensuring good watertightness and protection against the elements.

REM modul REM modul strop mob

Ceiling composition

The outer layer of the unit consists of a 0,5 mm thick coated sheet metal. The sheeting is sloped and serves as protection against weather elements.
The thermal insulation of the ceiling can be customized to comply with the required U-values using different thicknesses and types of insulation.

Standard interior ceiling coverings include:

10 mm thick chipboard, foil-coated, white.
Shallow profiled coated sheet metal, thickness 0.5 mm.
Mavčno kartonaste plošče 12.5 mm thick gypsum board.

REM modul REM modul sestava stropa

Extreme flexibility

The figures above are used for informational purposes only. Individual unit elements can be customised to your requirements.
REM modul REM modul sestava stropa
Zvočna izoliranost

43 (-5, -12) dB - 49 (-1, -6) dB

Laboratorijsko izmerjene vrednosti (EN 10140-1, EN 10140-2, EN 10140-4, EN 10140-5)

Odtok deževnice
v stebrih

Wall

The external wall of the module is the main dividing barrier between the exterior and the interior. Different wall compositions are used to comply with the required energy, sound and fire performance standards.

REM modul REM modul stena mob

Wall composition

Chipboard
10 mm thick, foil-coated, white.
Flat coated sheet metal thickness 0.5 mm.
Gypsum board
12.5 mm thick.

The thickness of the glass wool thermal insulation can be adapted to the required U-values.

The outer layer of the unit consists of a 0,5 mm thick coated sheet metal.

Any modular building built with the REM module system can be upgraded with a secondary ventilated facade.

The panels come in standard dimensions of 1145 mm.

REM modul REM modul stena steklena volna prerez

Extreme flexibility

The figures above are used for informational purposes only. Individual unit elements can be customised to your requirements.
REM modul REM modul stena steklena volna prerez
Partition walls
Partition walls shall be equal in height to the internal height of the room and may be erected either prematurely or on site. We offer partition walls with different external coverings and fillers.

Floor

The main function of a floor is to withstand stress and wear. The floor in REM modular units can be customized to withstand all types of loads.

REM modul REM modul pod mob

Floor composition

The floor coverings can consist of:
PVC
Rubber
Elastic self-leveling coating
Aluminium ribbed sheet metal
Ceramic tiles
Laminate flooring

The colour, thickness and dimensions of the floor covering is customized according to the project specifications.

Wood cement board, 20 mm thick.

The thermal insulation of the floor can be customized to comply with the required U-values using different thicknesses and types of insulation.

Top layer of galvanised sheet metal with a thickness of 0.5 mm

REM modul REM modul sestava poda prerez

Extreme flexibility

The figures above are used for informational purposes only. Individual unit elements can be customised to your requirements.
REM modul REM modul sestava poda prerez
Floor profile height

In addition to the standard floor profile heights of 120 and 170 mm, we can also produce floor profiles in other dimensions upon request.

Forklift pockets

Different forklift attachment pockets can be made in the floor profiles according to the customer's requirements, to allow easier handling of the units.

Doors and windows

PVC, wood or aluminium windows and doors

Window glazing can be adapted to comply with different energy and material requirements as well as required custom dimensions. The dimensions of entrance and interior doors can be customised, and they can be made of various materials and equipped with different accessories to add function to the finished object.

Installations

Electrical installations and equipment.

The majority of the electrical installations in the units are pre-prepared and only minor finishing works are required on site. We can comply with a variety of electrical installation standards and designs.

Sanitary installations
and equipment.

Various options for sanitary installations and equipment are available for selection. Sanitary facilities can be designed in a variety of ways, with sanitary fittings and equipment to suit the customer’s requirements.

Various heating
options

The modular units can be equipped with different central or local heating systems. In accordance with the designs, we prepare everything necessary for the system of your choice.

Ventilation
systems

We offer the option of a partial implementation of local or central ventilation systems according to a ventilation implementation plan.

CONNECTIVITY

Connecting modules

With the REM module system, you can place an infinite number of units side-by-side and stack as many as three modules on top of one another.

3x

modules
on top of each other

REM modul Infinite final

modules
alongside one another

References

This site is registered on wpml.org as a development site. Switch to a production site key to remove this banner.